 FLAT RIBBON WIREstarting of main content Single Core Wire

                             Single Core Wire





For IDC Connection


Flat Ribbon Wire

UL STYLE       : 2651
Rating             : 105 °C, 300V
Standards       :  UL 758, CSA C22.2 No.210.2
Usage             :  For internal wiring of audio/video/multimedia equipment

Conductor
Insulation
Conductor Resistance
at 20oC
(Max)
W/km
Approx. Weight   kg/km
Unit Length Spool m
Type    
No    
Size   AWG
Stranding   No./mm
Diameter   mm
Insulation Thickness mm
Thickness  mm
Width    mm
TA
2
26
7/0.16
0.48
0.41
1.30
2.70
139
6
1,200
3
4.10
9
800
4
5.50
12
600
5
6.90
15
500
6
8.30
18
400
2
24
7/0.203
0.61
0.35
1.30
2.70
85.9
7
1,200
3
4.10
11
800
4
5.50
14
600
5
6.90
18
500
6
8.30
22
400
2
22
7/0.26
0.78 
0.26 
1.30
2.70
55.7
9
850
3
4.10
14
550
4
5.50
19
450
5
6.90
23
350
6
8.30
28
300
*Single Layer Coil

1.Product Description

a) Conductor : Tinned Annealed copper wire (TA) Stranded
b) Insulation : Heat resistance lead free PVC. Light Grey colour

2.Features

a) Flammability : VW-1 (UL), FT1 (CUL), -F- (DENTORI).
b) Can be used with Insulation Displacement Contact(IDC) connectors

3. Wire Marking

AWM E41447-HCS STYLE 2651 **AWG 105C 300V VW-1 C LF
AWM I A 105C 300V FT1 **AWG HITACHI -F-

4.Safety Standards No.

a) E41447, CSA : LL41447, F-Mark : F-HCS1-003

5. Ordering Information

a) Contact us at mailto:sales@hitachicable.com.sg